Same-Day HERS Ratings — Fast turnaround & 24/7 support across Massachusetts 📞 (617) 501-6788 Free Quote

68 South St - Framingham MA

MA 01702

Energyconsultants01@gmail.com

Business Hr. 08:00-08:30

+1 (617) 501-6788

24/7 Support

Duct Leakage Testing • Middlesex County

Duct Leakage Testing Burlington MA

Certified duct leakage testing for Burlington, measured with a calibrated duct blaster and documented for your permit and HERS rating.

✓ Certified RESNET/HERS raters
✓ Permit-ready CFM25 reports
✓ Serving Middlesex County

Duct Leakage Requirements in Burlington

Burlington follows the Massachusetts Stretch Code, which caps total duct leakage at 4 CFM25 per 100 square feet. Our raters measure your ductwork in CFM25 and document a clear pass against the 4 CFM25 per 100 sq ft limit.

Project / code tierDuct leakage limitWhat is tested
Base energy code4.0 CFM25 / 100 sq ftDucts outside conditioned space
Stretch Code4 CFM25 / 100 sq ft (total)Total leakage or leakage to outside
Specialized Stretch Code3.0 CFM25 / 100 sq ftAll ducts, regardless of location
Ducts fully inside envelopeTest generally not requiredAir handler + ducts in conditioned space
3.0 Specialized4.0 Stretch / Baseleaky →tighter ductscode limit (CFM25/100 sq ft)

IECC Duct Leakage Thresholds Reference

Beyond the Massachusetts tier that applies in Burlington, these are the federal IECC duct-leakage limits across code editions. All values are CFM at 25 Pascals (CFM25) per 100 sq ft of conditioned floor area (CFA) unless noted.

2009 IECC

Test stageMeasurementLeakage limit
Postconstruction Leakage TestDuct Leakage to Outdoors≤ 8 CFM25 / 100 sq ft CFA
Rough-in with AHUTotal Duct Leakage≤ 6 CFM25 / 100 sq ft CFA
Rough-in without AHUTotal Duct Leakage≤ 4 CFM25 / 100 sq ft CFA

2012, 2015, 2018 & 2021 IECC — Prescriptive Paths

Test stageMeasurementLeakage limit
Postconstruction Leakage TestTotal Duct Leakage≤ 4 CFM25 / 100 sq ft CFA
Rough-in with AHUTotal Duct Leakage≤ 4 CFM25 / 100 sq ft CFA
Rough-in without AHUTotal Duct Leakage≤ 3 CFM25 / 100 sq ft CFA

2015 & 2018 IECC — Performance Path (Cost Compliance)

Leakage testing is required unless all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path.

2024 IECC — Prescriptive Path

Conditioned floor areaCondition at testTotal leakage limit
>1,000 sq ft CFASpace-conditioning equipment not installed< 3 return grilles: ≤ 3 CFM  ·  3+ return grilles: ≤ 4 CFM
>1,000 sq ft CFAAll components installed< 3 return grilles: ≤ 4 CFM  ·  3+ return grilles: ≤ 6 CFM
>1,000 sq ft CFAEquipment not installed, ducts entirely in conditioned space< 3 return grilles: ≤ 6 CFM  ·  3+ return grilles: ≤ 8 CFM
>1,000 sq ft CFAAll components entirely in conditioned space< 3 return grilles: ≤ 8 CFM  ·  3+ return grilles: ≤ 12 CFM
≤1,000 sq ft CFAEquipment not installed≤ 30 CFM
≤1,000 sq ft CFAAll components installed≤ 40 CFM
≤1,000 sq ft CFAEquipment not installed, ductwork entirely in conditioned space≤ 60 CFM
≤1,000 sq ft CFAAll components entirely in conditioned space≤ 80 CFM

How Duct Leakage Testing Works in Burlington

Conditioned spaceAirhandlerDuct blaster25 Pa

A duct blaster seals off your HVAC system and pressurizes it to 25 Pascals. The airflow needed to hold that pressure is your leakage rate in CFM25 — the lower the number, the tighter the ducts.

1. Seal registers
Cover every supply and return grille so the ducts form a closed system.
2. Connect duct blaster
Attach the calibrated fan to the return or air handler.
3. Pressurize to 25 Pa
Run the fan until the ductwork holds 25 Pascals.
4. Read CFM25
Record the airflow needed to hold pressure — your leakage rate.
5. Seal & verify
Fix any failing seams, then retest to confirm compliance.

Common Sources of Duct Leakage We Check in Burlington

Most duct leakage comes from a short list of predictable weak points. Knowing where to look is what turns a CFM25 number into a fixable list of locations.

Boot & register connections

The joint where a duct boot meets the drywall is the single most common leak point — often left unsealed behind the register grille.

Plenum & air-handler seams

Sheet-metal plenums and the cabinet of the air handler leak at seams and access panels unless mastic-sealed.

Disconnected flex runs

Flexible ducts can pull loose at collars or get crushed above insulation, dumping conditioned air into the attic.

Panned-joist returns

Return cavities framed from floor joists or wall studs are notoriously leaky and can draw in unconditioned air.

Building-cavity returns

Using framing cavities as return ducts pulls air from attics, garages, or crawlspaces instead of living space.

Trunk-line joints

Long supply trunks flex and separate at joints over time, especially where they were only taped rather than sealed with mastic.

Why Tight Ducts Keep Heat In Your Burlington Home

Unconditioned atticLiving spaceCrawlspaceleaks

In Burlington, leaky ducts quietly waste a large share of what your furnace or heat pump produces, sending warm or cool air into spaces no one lives in.

A verified-tight duct system means a right-sized furnace or heat pump can deliver its full output where it's needed, steadying comfort and cutting waste.

Less wasted air
DOE estimates 20–30% of conditioned air is lost to duct leaks.
Lower heating load
Sealed ducts cut run time and ease strain on the system.
Steadier comfort
Rooms hold temperature instead of running hot and cold.

What Your Burlington Duct Test Report Includes

You get a document your building department and HERS software will accept the first time — not just a number.

  • Measured total duct leakage in CFM at 25 Pascals (CFM25)
  • Leakage normalized per 100 sq ft of conditioned floor area
  • Clear pass/fail against the 4.0 CFM25 limit that applies in Burlington
  • The test method used (rough-in or post-construction) per ANSI/RESNET/ICC 380
  • Documentation formatted for your HERS rating and building-permit file
  • A punch list of leak locations if a re-seal and retest is needed

Best Fit for Projects Like

  • Projects in Specialized-Code towns that must hit 3.0 CFM25 per 100 sq ft on all ducts
  • Builders who need a fast, permit-ready duct test scheduled around drywall
  • Burlington new-construction homes needing a duct test to complete the HERS rating
  • Burlington projects that need both envelope air-tightness and duct testing documented in one visit
  • Additions in Burlington where new HVAC ducts must comply with Section R403

Duct Leakage Testing Burlington MA Facts

  • For a total duct leakage test, a window or door is left open to outside so the test fan measures the ducts alone and not the house.
  • There are two testing points: a rough-in test before drywall and a post-construction test with the air handler installed, so leaks can be caught while they are still easy to reach.
  • Duct leakage that lets humid air into cool supply runs — or moves moist air into cold cavities — can create the conditions for mold growth.
  • Sealing ducts with mastic or UL-181 rated tape at seams, joints, and boot connections is the standard fix; cloth 'duct tape' is not code-approved for this.

Trusted for Duct Leakage Testing Burlington MA

★★★★★
Great experience with HERS Rating & Duct Testing! The team was friendly, professional, and explained everything clearly.
— Rodrigo de Medeiros
★★★★★
Very thorough, informative and prompt! Highly recommend!
— Paul Chaisson
★★★★★
Best decision I made was hiring Home Energy Efficiency Consultants LLC. Their attention to detail and willingness to answer all my questions made the process stress-free.
— Yerly Ruiz

Our Massachusetts Service Locations

Serving clients from our Massachusetts locations in Everett, Somerville, and Framingham.

Everett Location

371 Main St
Everett, MA 02149

Somerville Location

519 Broadway
Somerville, MA 02145

Framingham Location

68 South St
Framingham, MA 01702

Duct Leakage Testing Burlington MA FAQ

What test pressure is used for duct testing?
The standard is 25 Pascals, which is close to the actual operating pressure of a typical residential duct system, so the measurement reflects real-world conditions.
What happens if my ducts fail the test?
We identify where the leaks are, you seal the seams and boots with mastic or UL-181 tape, and we retest. Because failing can delay your certificate of occupancy, catching it early keeps the project on schedule.
Do you serve Burlington and the surrounding area?
Yes. We provide duct leakage testing throughout Middlesex County and across eastern and central Massachusetts, with fast, permit-ready reporting.
Does duct sealing save money?
Yes. Because leaky ducts can force an HVAC system to work up to 50 percent harder, sealing them shortens run times, lowers utility bills, and reduces wear on the equipment.
When during construction should ducts be tested?
There are two points: a rough-in test before the walls are closed, and a post-construction test with the air handler installed. Testing at rough-in lets us catch and seal problems while the ductwork is still exposed and easy to reach.
What's the difference between total leakage and leakage to outside?
Total leakage seals every register and measures all air escaping the ducts, inside and out. Leakage to outside pressurizes the building envelope at the same time so only the air lost to unconditioned space — attics, crawlspaces, garages — is counted.

Get Started With Duct Leakage Testing Burlington MA

Fast scheduling and permit-ready CFM25 reports for Burlington and all of Middlesex County.

Call 617-501-6788

Certifications

certified home energy rater
International Code Council - ICC Membership Badge
hres raterm certified home energy rater

Stay Updated with Our Latest News

Sign up for our newsletter to receive exclusive updates, tips, and insights about energy-efficient building practices, financial incentives, and the latest energy code requirements in Massachusetts.

You have been successfully Subscribed! Ops! Something went wrong, please try again.

At Home Energy Efficiency Consultants, we are committed to providing the highest quality energy consulting services to homebuilders, architects, and developers across Massachusetts.

Contact Details

+1 (617) 501-6788

24/7 Support

68 South St - Framingham MA

MA 01702

Energyconsultants01@gmail.com

Business Hr. 08:00-08:30

© 2025, All Rights Reserved.

Home Energy Efficiency Consultants — 4 Massachusetts Locations — (617) 501-6788519 Broadway, Somerville, MA 02145  •  68 South St, Framingham, MA 01702  •  272 Lincoln St C1, Marlborough, MA 01752  •  371 Main St, Everett, MA 02149
ENERGY STAR PartnerU.S. Department of Energy Efficient New Home Partner verified listingMass Save partner logoENERGY STAR® Partner  ·  U.S. DOE Efficient New Home Partner — Verified  ·  Your Trusted Mass Save® Partner
Statewide service: HERS Ratings Massachusetts — Home Energy Efficiency Consultants

Before you go — get a free quote

Same-day HERS ratings & blower door testing across Massachusetts. We respond within hours.

Get My Free Quote →