REScheck & COMcheck Sharon MA - Quick Facts
Local energy code in Sharon
- Sharon adopted the Massachusetts Specialized (Opt-In) Energy Code effective January 1, 2025; the Stretch Code applies as the baseline. IECC Climate Zone 5A.
- Beyond the Stretch baseline, new mixed-fuel homes must be pre-wired for future electrification and add on-site solar where there is significant unshaded roof space.
- All-electric new homes must use heat pumps for space heating and hot water; fossil-fuel homes over 4,000 sq ft must reach net-zero (HERS 0), and new multifamily over 12,000 sq ft must meet Passive House.
REScheck & COMcheck in Sharon
- REScheck documents the prescriptive residential path for Sharon additions, alterations and renovations (from $300); new-construction performance projects use a full HERS energy model instead.
- Commercial projects use COMcheck for the prescriptive path (from $600); larger new commercial buildings need third-party performance certification under the Stretch Code.
- 24-48 hour turnaround - documentation ready to upload with your Sharon permit application.
2026 Mass Save incentives in Sharon
- All-electric renovations and additions can earn Mass Save incentives up to $20,000 (Level 1) or $30,000 (Level 2) for a single-family home, verified by a RESNET-certified HERS rater.
RESNET-certified · 15,000+ ratings completed · 5.0 stars across 135 Google reviews · (617) 501-6788
REScheck & COMcheck Sharon MA
Fast, accurate REScheck and COMcheck energy code compliance reports for residential and commercial projects in Sharon, Massachusetts. We prepare the documentation your building department needs to issue a permit — without the cost of a full performance-path energy rating when your project does not require one.
What we deliver
A stamped, signed compliance report matched to your plans and ready to upload with your Sharon building permit application.
REScheck vs. COMcheck: What’s the Difference?
REScheck and COMcheck are DOE-developed programs that show a building meets the IECC energy code. Which one your Sharon project needs depends on whether the work is residential or commercial — here is how they differ.
What is a REScheck?
For homes, REScheck is the go-to. This DOE program checks residential envelopes — detached houses and multifamily up to three stories — and allows insulation and fenestration trade-offs to show prescriptive or component-based IECC compliance.
What is a COMcheck?
COMcheck handles commercial work and high-rise residential of four stories or more. The DOE tool evaluates envelope, lighting (interior and exterior), and mechanical systems against either the IECC or ASHRAE 90.1, with trade-offs allowed across components.
REScheck Projects in Sharon
REScheck is the simplest path for smaller residential projects in Sharon that do not trigger a full performance-path energy rating. It is typically the right tool when your project is:
- New residential construction or an addition under 1,200 square feet that does not require a HERS rating
- Additions, alterations, or renovations to a one- or two-family home
- Multifamily buildings of three stories or fewer
- Finished basements, attic conversions, and dormer additions on existing homes
- Permit applications needing residential envelope documentation on the prescriptive or UA trade-off path
COMcheck Projects in Sharon
COMcheck is required for commercial and larger projects in Sharon. Reach for a COMcheck when your project involves:
- Commercial buildings — offices, retail, restaurants, warehouses, and mixed-use
- New mechanical (HVAC) or service water heating systems in commercial spaces
- Medical, dental, and professional office construction
- Restaurant build-outs and retail white-box improvements
- Tenant fit-outs and interior or exterior lighting alterations
What Your Sharon Compliance Report Includes
Fast, permit-ready turnaround
We deliver documentation ready to upload with your building permit application, and we answer plan-review questions if the department asks for revisions.
REScheck report
A signed REScheck compliance certificate matched to your plans, the inspection checklist, and the UA trade-off summary showing your insulation R-values and window U-factors meet the residential energy code.
Plans matched to code
We enter your assemblies, fenestration, and (for commercial) lighting and mechanical details exactly as designed, so the report reflects what you are actually building in Sharon.
COMcheck report
The COMcheck Envelope, Lighting, and Mechanical Compliance Certificates plus the Plan Review Checklist — the full package a commercial plan reviewer expects for permit submission.
Serving Sharon and Norfolk County
Sharon sits in Norfolk County, Massachusetts, in IECC climate zone 5A — the cold-climate zone that drives the insulation and air-sealing levels your REScheck or COMcheck must document. We prepare compliance reports for projects throughout Norfolk County, matched to the code edition Sharon currently enforces.
Transparent Pricing for Sharon Compliance Reports
Transparent starting prices. Final cost depends on project size, number of assemblies, and scope.
- REScheck (residential): starting at $300
- COMcheck (commercial): starting at $600
- Revisions to match plan-review comments are handled promptly
REScheck reports start at $300 and COMcheck reports start at $600 for projects in Sharon. Send your plans for an exact quote.
Trusted by Sharon Builders & Owners
Google Review
“Best decision I made was hiring Home Energy Efficiency Consultants LLC. Their attention to detail and willingness to answer all my questions made the process stress-free.”
Need a REScheck or COMcheck in Sharon?
Send us your plans and we will tell you which report you need and get it back to you fast — ready for your Sharon permit.
Email Energyconsultants01@gmail.com Call 617-501-6788HERS Ratings Across Sharon and Nearby Communities
Home Energy Efficiency Consultants rates new homes, additions, and major renovations throughout Sharon — including Sharon Center, and Sharon Heights. Every Sharon project is filed with the Town of Sharon Building Department, and we handle the energy model, blower door and duct leakage testing, and the compliance paperwork from start to finish.
We also serve the communities right around Sharon, including Canton, Stoughton, Foxborough, Walpole, and Norwood. Our Framingham office at 68 South St is the closest of our four Massachusetts locations — see our Framingham office or call (617) 501-6788 to get a Sharon rating on the schedule.
Sharon Specialized Energy Code — HERS Index Targets
Sharon enforces the Massachusetts Specialized (Opt-In) Energy Code. The required HERS score depends on fuel type and project scope — a lower index is stricter.
| Project type | Mixed-fuel | Mixed-fuel + solar | All-electric | All-electric + solar |
|---|---|---|---|---|
| New construction | HERS 42 | 42 | 45 | 45 |
| New construction — embodied-carbon credit | 45 | 45 | 48 | 48 |
| Accessory dwelling unit (ADU) | 52 | 55 | 55 | 58 |
| Major alteration / renovation / change of use | 65 | 70 | 70 | 75 |
A HERS rating is triggered by new construction, additions over 1,000 sq ft (or more than 100% of the existing conditioned area), and Level 3 alterations over 1,000 sq ft affecting more than 50% of the home. New homes must also pass a blower-door test at 3.0 ACH50 and include electrification-ready wiring for heat pumps, EV charging, and solar. We model your Sharon project up front so you know the exact target and the fastest path to hit it — call (617) 501-6788.
More Massachusetts Towns We Serve
Certified HERS ratings, blower door testing and energy code compliance across all 351 Massachusetts cities and towns.