In Massachusetts, improving comfort and cutting energy bills through better insulation and air sealing matters year-round. Our team helps Hanson homeowners choose and install the insulation that fits their home and meets code.

New construction & retrofitBlower-door-ready resultsCode-compliant R-valuesAttic & roof-deck insulation

Two Types of Spray Foam, Two Jobs

Spray foam comes in two families, and the right choice shapes both performance and cost on a Hanson project.

Closed-Cell Spray Foam

Dense and rigid at roughly R-6 to R-7 per inch — the highest R-value of common insulation. It also acts as an air and vapor barrier and adds stiffness, making it ideal for rim joists, basements, crawlspaces, and roof decks in Hanson homes.

Open-Cell Spray Foam

Lighter and vapor-permeable at about R-3.5 to R-3.8 per inch. It expands to fill irregular cavities, seals air leaks, and dampens sound — a strong choice for interior walls and attics where drying potential matters.

Comparing Insulation Materials by R-Value

R-value measures resistance to heat flow — higher is better. Here is how the insulation materials used on Hanson, Hanson projects compare per inch of thickness.

Open-cell spray foam

R-3.5 to R-3.8 / inch

Lighter and vapor-permeable; expands fully to fill irregular cavities, seals air leaks and dampens sound. A common choice for interior walls and vented attics.

Cellulose (dense-pack)

R-3.2 to R-3.8 / inch

Recycled paper fiber treated for fire and pests; dense-packs into closed wall cavities, making it ideal for retrofits.

Fiberglass blown-in

R-2.2 to R-2.9 / inch

Loose-fill for open attic floors; fast to install and settles into an even blanket over large horizontal areas.

Polyiso rigid board

R-5.6 to R-6.5 / inch

The highest-R rigid foam board; foil-faced and used for continuous exterior insulation to stop thermal bridging.

XPS rigid board

R-5.0 / inch

Extruded polystyrene; moisture-resistant rigid board common under slabs and on foundation walls.

Fiberglass batts

R-2.9 to R-3.8 / inch

The most common and economical insulation; must be cut and fitted carefully because gaps and compression sharply reduce real-world performance.

Mineral wool (rock wool)

R-4.0 to R-4.3 / inch

Dense, naturally fire-resistant and water-repellent batts or boards with excellent sound control; keeps its R-value when wet.

EPS rigid board

R-3.6 to R-4.2 / inch

Expanded polystyrene; the most affordable rigid foam, used for continuous exterior and below-grade insulation.

Wood fiber

R-3.4 to R-4.0 / inch

Renewable, carbon-storing batts and boards with strong sound dampening and vapor-open performance.

Closed-cell spray foam

R-6 to R-7 / inch

The highest R-value of any common insulation; also acts as an air and vapor barrier and adds structural rigidity. Ideal for rim joists, basements, crawlspaces and unvented roof decks.

Hiring the Right Insulation Pro in Hanson

Spray foam involves chemical reactions and strict safety steps, so the installer matters. In Hanson, look for a contractor who:

  • Knows Massachusetts code, including ignition and thermal barrier requirements
  • Documents R-values and provides what you need for code sign-off
  • Follows OSHA safety practices with proper ventilation and respirators during spraying
  • Carries general liability and workers’ compensation coverage
  • Manufacturer-certified to install specific foam systems and keep warranties valid
  • Licensed and fully insured for insulation work in Massachusetts

Why Hanson Homes Need the Right Insulation

Because Hanson sits in Hanson and IECC Climate Zone 5A, insulation and air sealing carry a real payback. We match materials and methods to a mix of colonials, capes, ranches, and newer construction so the work lasts and performs.

Meeting the Massachusetts Energy Code

Hanson falls in IECC Climate Zone 5A. New and renovated homes must meet these minimum insulation levels under the Massachusetts energy code.

AssemblyMinimum R-value (Zone 5)
Wood-frame wallsR-20, or R-13 cavity + R-5 continuous
Ceilings / atticsR-49 to R-60
Floors over unconditioned spaceR-30
Basement wallsR-15 continuous or R-19 cavity
Crawlspace wallsR-15 continuous or R-19 cavity
Slab edge (heated)R-10, 2 ft deep

Where Spray Foam Works in Hanson Homes

Attics & roof decks

The top source of heat loss; foam on the roof deck creates a conditioned, sealed attic.

Exterior walls

Foam fills stud cavities completely, eliminating the gaps that reduce batt performance.

Garage ceilings

Insulating below living space keeps floors warm and blocks fumes.

Cathedral ceilings

Foam insulates tight roof-line assemblies where batts cannot breathe or fit well.

Rim & band joists

A major air-leak point where the foundation meets framing; closed-cell foam seals and insulates it.

Bonus rooms & knee walls

Sealing these awkward areas fixes the hot-and-cold rooms common over garages.

Combining Closed-Cell and Fill Insulation

Filling an entire framing bay with closed-cell foam is effective but expensive. A smarter build layers a modest amount of closed-cell against the outer sheathing for the air seal and vapor control, then tops up the cavity with a lower-cost material to finish the R-value.

1

The Flash — Closed-Cell

That initial closed-cell pass — placed tight to the sheathing — provides the air barrier and the vapor control the assembly needs, and at about R-6.5 per inch a two-inch layer adds roughly R-13.

2

The Fill

The rest of the bay is then completed with open-cell foam, dense-pack cellulose, or fiberglass to bring the wall up to target.

Worked Example — R-30 Wall

A typical Massachusetts R-30 build stacks a 2-inch closed-cell layer (≈ R-13) with 4.5–5 inches of open-cell foam or dense-pack cellulose (≈ R-16–18) to total roughly R-30 in one 2×6 cavity.

Keeping the impermeable closed-cell on the cold, outer face keeps the sheathing above the dew point, so moisture can't condense inside the wall — the key rule is making that foam layer thick enough for our Zone 5 climate.

Frequently Asked Questions

Is spray foam safe once it is installed?

Once cured, spray foam is inert and safe. A qualified installer follows manufacturer cure times, ventilation, and — where code requires — an ignition or thermal barrier over the foam.

What R-value do I need in Hanson?

In Climate Zone 5, the code targets roughly R-20 (or R-13 + R-5 continuous) in wood-frame walls, up to R-60 in attics, and R-15 continuous on basement walls. The exact number depends on the assembly and project type.

What is the difference between open-cell and closed-cell foam?

Closed-cell foam is denser, delivers about R-6 to R-7 per inch, and acts as an air and vapor barrier — good for rim joists, basements, and roof decks. Open-cell is lighter, about R-3.5 to R-3.8 per inch, vapor-permeable, and often used in walls and attics.

How much does spray foam insulation cost?

Cost depends on the foam type, the square footage, and how many inches of thickness the assembly needs, so a garage, an attic, and a whole-home retrofit all price differently. Rather than quote a number that won't fit your home, we assess the Hanson project and give you a written, itemized estimate. Request a quote and we'll walk you through the options.

How much insulation does an attic need?

Massachusetts code targets about R-49 to R-60 in attics. Because attics are usually the biggest source of heat loss, they are often the most cost-effective place to add insulation first.

What R-value is required for spray foam in Massachusetts?

Massachusetts sits in Climate Zone 5. Above-grade walls generally need about R-20 (or R-13 cavity plus R-5 continuous), attics roughly R-49 to R-60, floors over unconditioned space about R-30, and basement or crawlspace walls around R-15 continuous. We size the foam on every Hanson project to the value your assembly needs to pass code.

What R-value do you get from 2 inches of closed-cell spray foam?

At about R-6.5 to R-7 per inch, two inches of closed-cell foam gives roughly R-13, and that layer also air-seals the cavity and controls vapor. On many Hanson walls we pair a 2-inch closed-cell flash with a lower-cost fill to reach the full target economically.

How do you reach R-30 in a wall with spray foam?

The most cost-effective route is a flash-and-fill assembly: about 2 inches of closed-cell foam (≈ R-13) against the sheathing, then the rest of the cavity filled with open-cell, dense-pack cellulose, or batt (≈ R-16 to R-18). In a standard Hanson 2x6 wall that combination lands right around R-30.

Does Mass Save cover spray foam insulation?

Mass Save is a real Massachusetts efficiency program that Hanson homeowners can explore. It typically funds a no-cost home energy assessment and offers incentives toward weatherization and air sealing; coverage for spray foam specifically can vary and often depends on the assessment, so we help you understand what your project may qualify for.

Certifications

certified home energy rater
International Code Council - ICC Membership Badge
hres raterm certified home energy rater

Stay Updated with Our Latest News

Sign up for our newsletter to receive exclusive updates, tips, and insights about energy-efficient building practices, financial incentives, and the latest energy code requirements in Massachusetts.

You have been successfully Subscribed! Ops! Something went wrong, please try again.

At Home Energy Efficiency Consultants, we are committed to providing the highest quality energy consulting services to homebuilders, architects, and developers across Massachusetts.

Contact Details

+1 (617) 501-6788

24/7 Support

68 South St - Framingham MA

MA 01702

Energyconsultants01@gmail.com

Business Hr. 08:00-08:30

© 2025, All Rights Reserved.

Before you go — get a free quote

Same-day HERS ratings & blower door testing across Massachusetts. We respond within hours.

Get My Free Quote →