68 South St - Framingham MA

MA 01702

Energyconsultants01@gmail.com

Business Hr. 08:00-08:30

+1 (617) 501-6788

24/7 Support

Blower Door Testing Edgartown MA - Quick Facts

Local energy code in Edgartown

  • Edgartown is a Stretch Code community - the statewide baseline for new construction and major renovations. IECC Climate Zone 5A.
  • Massachusetts has three energy-code levels - base (2021 IECC), Stretch, and Specialized (Opt-In) - and Edgartown is on the Stretch Code.

Blower door requirement in Edgartown

  • New homes in Edgartown must test at 3.0 ACH50 or tighter under the Massachusetts Stretch Code.
  • Air-leakage testing is mandatory, measured with a calibrated blower-door fan to the RESNET / ASTM protocol - there is no inspection-only substitute for the result.
  • Companion duct leakage limit: 4.0 CFM25 per 100 sq ft of conditioned floor area total leakage (8.0 when all ducts are inside conditioned space - the test is still required).
  • Same-day preliminary results; final report in 24-48 hours, filed with the Edgartown building department.

Mass Save rebates for Edgartown (2026)

  • A tight result unlocks Mass Save all-electric incentives ($7,500 to $25,000 per new single-family home); an all-electric renovation testing at 3.0 ACH50 or better reaches the Level 2 tier, up to $30,000.
  • Incentives require a Mass Save-approved, RESNET-certified HERS rater.

RESNET-certified · 15,000+ ratings completed · 5.0 stars across 136 Google reviews · (617) 501-6788

Massachusetts Blower Door Testing

Blower Door Testing Edgartown MA

Certified blower door testing in Edgartown - we measure your home's air-tightness in ACH50, pinpoint leaks, and document a passing result for your building permit.

✓ Certified RESNET/HERS raters✓ Fast permit-ready reports✓ Serving Dukes County

Air-tightness at a glance

LeakyTight11+very leaky5.0remodel3.0new build0.6Passive
3.0ACH50 new build
5.0ACH50 remodel
50 Patest pressure

Blower Door Testing Edgartown MA

A blower door test is the code-required way to prove how airtight a home in Edgartown really is. A calibrated fan depressurizes the house to 50 Pascals so we can measure exactly how much air leaks through the envelope, reported as air changes per hour (ACH50). New construction must reach 3.0 ACH50 or lower, and no home on any compliance path may exceed 5.0 ACH50 (IECC 2021 R402.4.1.2).

Project typeMax ACH50Notes
New construction3.0 or lowerMandatory blower-door test under R402.4.1.2
Maximum on any compliance path5.0Code cap under IECC 2021 R402.4.1.2
Addition < 1,000 sq ftExempt*May be exempt from testing (R502.3.1)
Passive House (PHI; Phius uses 0.06 CFM50/sq ft)0.6Whole-building test, Phius/PHI protocol

*Confirm with your local building department. Requirements per the 2025 MA Stretch Energy Code Technical Guidance.

How Blower Door Testing Works in Edgartown

Exterior doorwayCalibrated fan @ 50 Pa

The fan mounts in an exterior doorway and holds the home at a fixed 50-Pascal pressure difference - about what a 20 mph wind would exert. The airflow required to maintain that pressure, in CFM, converts to ACH50 using the home's conditioned volume.

The code converts the result to Q50 (CFM at 50 Pa) with Q50 = (Volume × ACH50) ÷ 60. A 2,700 sq ft home at 2 ACH50 works out to roughly 810 CFM50.

Step 1
Seal & set up
A calibrated fan is fitted into an exterior doorway and the home is prepared - interior doors open, exterior closed.
→
Step 2
Depressurize to 50 Pa
The fan pulls air out until the home sits 50 Pascals below outdoor pressure, mimicking a steady 20 mph wind.
→
Step 3
Measure airflow
The airflow needed to hold that pressure is recorded in CFM and converted to ACH50 using the home's volume.
→
Step 4
Locate leaks
Smoke, an infrared camera, or hand-feel pinpoint leaks at rim joists, top plates, penetrations and windows.
→
Step 5
Seal & verify
Any leaks are sealed and the home is retested until it documents a passing result for the permit file.

Keeping Heat In During Edgartown Cold Spells

Air-leakage heat loss grows with the gap between indoor and outdoor temperature, which is why a drafty home feels worst in a deep freeze. Warm air you have paid to heat escapes high, cold air rushes in low, and the heating system ends up chasing a load that keeps climbing as the temperature drops.

Once the leaks are found and sealed, the home retains heat far longer between heating cycles. Floors stay warmer, temperatures hold steady on windy nights, and the reduced heating load shows up directly on winter utility bills.

warm air escapes highcold air pulled in low

Lower heating load

Less infiltration means a smaller winter heat-loss load and equipment that can keep up.

Retain paid-for heat

Warm air stays in the living space instead of escaping out the top of the house.

Steadier comfort

Fewer cold-floor drafts and a temperature that holds between heating cycles.

Where Edgartown Homes Leak Air

During depressurization the leaks are exaggerated, making them easy to find. In Dukes County's older housing stock the usual suspects are rim joists, top plates, attic hatches, recessed lights, and penetrations for plumbing and wiring. Coastal and exposed sites feel wind-driven infiltration most, so a tight, verified envelope pays back quickly here.

attic / top platerim joistwindowsdoorspenetrations

Best Fit for Projects Like

  • Pre-drywall diagnostic testing for builders
  • Gut renovations and deep-energy retrofits
  • Custom and high-performance builds
  • New single-family homes needing a code compliance test
  • Drafty existing homes seeking targeted air sealing

Blower Door Testing Edgartown MA Facts

Steadier indoor temperature

A tight home holds its heat longer between heating cycles, so rooms stay at a steadier temperature and recover faster after a cold, windy night.

Ties into ventilation

Because a tight home needs mechanical fresh air, the verified blower-door rate feeds the R403.6 ventilation sizing under ASHRAE 62.2 - air sealing and ventilation are designed together.

Moisture protection

Controlling air movement also controls the moisture that rides with it, protecting insulation and framing from condensation and mold over the life of the home.

New construction target

New residential construction in Massachusetts must test at 3.0 ACH50 or lower. Tighter is better, and many high-performance builders aim well under that number.

Trusted for Blower Door Testing Edgartown MA

★★★★★

I worked with this HERS rating company in South Boston on a remodel project and was able to get back 30,000 in rebates.

Samantha SugaGoogle Review
★★★★★

Best decision I made was hiring Home Energy Efficiency Consultants LLC. Their attention to detail and willingness to answer all my questions made the process stress-free.

Yerly RuizGoogle Review
★★★★★

Five stars isn't enough. The team at Home Energy Efficiency Consultants LLC goes above and beyond every time. They're the gold standard for HERS ratings in Massachusetts.

Miguel GilGoogle Review

Our Massachusetts Service Locations

Serving clients from our Massachusetts locations in Everett, Somerville, and Framingham.

Everett Location

371 Main St
Everett, MA 02149

Somerville Location

519 Broadway
Somerville, MA 02145

Framingham Location

68 South St
Framingham, MA 01702

Real blower door tests by HEEC for Edgartown projects

These are photos from Home Energy Efficiency Consultants blower door testing jobs in Massachusetts — the same equipment and setup our certified raters bring to Edgartown homes.

Blower door frame in a white entry door with the gauge and tubing on the floor – HEEC blower door testing for Edgartown, MA homes
Blower door frame in a white entry door with the gauge and tubing on the floor
Blower door fan running in a French-style glass door with the gauge on the wall – HEEC blower door testing for Edgartown, MA homes
Blower door fan running in a French-style glass door with the gauge on the wall

FAQ About Blower Door Testing Edgartown MA

What is the threshold for a remodel?

Remodels and alterations to existing homes are allowed up to 5.0 ACH50, a more realistic target given that older assemblies are harder to seal than new framing.

How tight is a Passive House?

PHI Passive House projects must test at 0.6 ACH50 or lower. Phius projects use a different limit: 0.06 CFM50 per square foot of building enclosure (0.08 for non-combustible buildings of 5+ stories), verified with a multi-point whole-building blower door test.

What happens if my home fails the test?

The rater locates the leaks with smoke, an infrared camera, or by feel, those areas are sealed, and the home is retested until it meets the target.

Do you work with builders and homeowners?

We work with builders, remodelers, designers, and homeowners - from single tests for permit sign-off to pre-drywall diagnostics that catch problems early.

Does a tighter house need mechanical ventilation?

Yes. A tight home relies on balanced mechanical ventilation for fresh air, and the code sizes that ventilation (R403.6 / ASHRAE 62.2) using your verified blower-door rate.

Why does air leakage matter for my heating bill?

Uncontrolled leakage can add 30% or more to heating and cooling costs. Every cubic foot of heated air that leaks out has to be reheated, so a tight envelope directly lowers your load.

Blower Door Test Requirements for Edgartown Projects

Edgartown is not on the Specialized Code list, so new homes follow the Massachusetts Stretch Code (225 CMR 22.00), adopted by 242 communities, or the base code if Edgartown has not adopted it. The testing requirements below come from 225 CMR 22.00 and the 2021 IECC it amends.

New single-family home construction - blower door testing in Edgartown, MAClosed-cell spray foam on exterior wall framing - blower door testing in Edgartown, MAClosed-cell spray foam in wall cavities - blower door testing in Edgartown, MA
RequirementLimitSource
New home, prescriptive path3.0 ACH50 or lowerIECC 2021 R402.4.1.3 (Climate Zone 5, all of Massachusetts)
Maximum on any compliance path5.0 ACH50 or 0.28 CFM50 per sq ft of enclosureIECC 2021 R402.4.1.2
Attached homes and apartments tested unit by unit0.30 CFM50 per sq ft of unit enclosure (alternative)IECC 2021 R402.4.1.2 exception
Mass Save ENERGY STAR tier1.5 ACH50 or lowerMass Save new construction program
Passive House (PHI)0.6 ACH50 or lowerPassive House Institute
Passive House (Phius)0.06 CFM50 per sq ft of enclosure (0.08 for non-combustible 5+ stories)Phius 2024 Certification Guidebook

How the house is set up for the test

  • Exterior windows and doors closed, with no sealing beyond normal weatherstripping
  • Dampers closed but not taped, and interior doors open
  • Exterior ventilation openings sealed, heating and cooling turned off, supply and return registers open
  • Tested at 50 Pascals per ANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827, with a signed report for the Edgartown building department

Sources: 225 CMR 22.00 (2025 edition) and the 2021 IECC sections listed. Edgartown is in Dukes County, served from our Framingham (68 South St) office.

Blower Door Questions from Edgartown Builders

What blower door number does a new home in Edgartown need?

On the prescriptive path the 2021 IECC requires 3.0 ACH50 or lower in Massachusetts, and no home on any path may exceed 5.0 ACH50. Homes on the HERS path are tested the same way, and the result goes into the HERS model, so a tighter house earns a lower HERS score.

What is ACH50?

Air changes per hour at 50 Pascals: how many times the home's air volume leaks out each hour while a blower door holds the house at 50 Pa. ACH50 = CFM50 × 60 ÷ conditioned volume.

How are townhouses and apartments tested?

Each dwelling unit can be tested on its own and meet 0.30 CFM50 per square foot of the unit's enclosure, which counts walls, floor and ceiling shared with neighbors. Large buildings may also get a whole-building test.

What gets taped or closed during the test?

Windows and exterior doors are closed, dampers are closed but not sealed, and exterior ventilation openings such as bath fan and ERV/HRV terminations are sealed. Interior doors stay open and the heating and cooling system is off.

When should the blower door test happen?

The code test happens at the end of construction. We recommend a pre-drywall test once the air barrier is complete, when leaks are cheap to find and fix, so the final test is a formality.

How much does blower door testing cost in Edgartown?

Pricing depends on the size of the building and the number of units. Send your plans or address and we will quote the test, or bundle it with your HERS rating and duct test in one visit.

Related: Duct leakage testing in Edgartown · HERS rating in Edgartown · Stretch Code help in Edgartown

Get Started With Blower Door Testing Edgartown MA

Book a certified blower door test and get a permit-ready air-tightness report. Call 617-501-6788.

The Phius Certified Verifier logo is used under license from Phius.

25+Years Experience
15,000+HERS Ratings
2,000+Units Completed
250+New Construction Builds
1365★ Google Reviews
✓ Unrestricted CSL License #CS-116975✓ RESNET Certified HERS Rater✓ Mass Save®-Listed HERS Rater

Last updated · Home Energy Efficiency Consultants, RESNET-certified HERS raters

HERS Ratings in Edgartown, Massachusetts

Home Energy Efficiency Consultants provides Edgartown with certified HERS ratings, blower door and duct leakage testing, and Massachusetts energy-code compliance for new construction, additions, and major renovations — with same-day preliminary reports.

We rate homes across the Commonwealth from our four offices. Reach the one nearest your Edgartown project — Somerville, Framingham, Marlborough, or Everett — or call (617) 501-6788 to schedule a Edgartown rating.

Home Energy Efficiency Consultants serves Edgartown, MA from four offices statewide. Find your nearest office or call (617) 501-6788.

More Massachusetts Towns We Serve

Certified HERS ratings, blower door testing and energy code compliance across all 351 Massachusetts cities and towns.

Certifications

certified home energy rater
International Code Council - ICC Membership Badge
Certified Home Energy Rater - RESNET HERS rater certification badge
Phius Certified Verifier logo - Home Energy Efficiency Consultants, Phius Passive House verification in Massachusetts

Stay Updated with Our Latest News

Sign up for our newsletter to receive exclusive updates, tips, and insights about energy-efficient building practices, financial incentives, and the latest energy code requirements in Massachusetts.

You have been successfully Subscribed! Ops! Something went wrong, please try again.

At Home Energy Efficiency Consultants, we are committed to providing the highest quality energy consulting services to homebuilders, architects, and developers across Massachusetts.

Contact Details

+1 (617) 501-6788

24/7 Support

68 South St - Framingham MA

MA 01702

Energyconsultants01@gmail.com

Business Hr. 08:00-08:30

© 2026, All Rights Reserved.

The Phius Certified Verifier logo is used under license from Phius.

Home Energy Efficiency Consultants — 4 Massachusetts Locations — (617) 501-6788519 Broadway, Somerville, MA 02145  •  68 South St, Framingham, MA 01702  •  272 Lincoln St C1, Marlborough, MA 01752  •  371 Main St, Everett, MA 02149
ENERGY STAR PartnerU.S. Department of Energy Efficient New Home Partner verified listingENERGY STAR® Partner  ·  U.S. DOE Efficient New Home Partner — Verified  ·  Mass Save®-Listed HERS Rater
Statewide service: HERS Ratings Massachusetts — Home Energy Efficiency Consultants
⚡ Same-Day HERS Ratings — Fast turnaround & 24/7 support across Massachusetts 📞 (617) 501-6788 Free Quote
⚡

Before you go — get a free quote

Same-day HERS ratings & blower door testing across Massachusetts. We respond within hours.

Get My Free Quote →