Blower Door Testing Westwood MA
Certified blower door testing in Westwood - we measure your home's air-tightness in ACH50, pinpoint leaks, and document a passing result for your building permit.
Air-tightness at a glance
Blower Door Testing Westwood MA
A blower door test is the code-required way to prove how airtight a home in Westwood really is. A calibrated fan depressurizes the house to 50 Pascals so we can measure exactly how much air leaks through the envelope, reported as air changes per hour (ACH50). New construction must reach 3.0 ACH50 or lower, while remodels are allowed up to 5.0 ACH50.
| Project type | Max ACH50 | Notes |
|---|---|---|
| New construction | 3.0 or lower | Mandatory blower-door test under R402.4.1.2 |
| Remodel / alteration | 5.0 | Realistic target for existing assemblies |
| Addition < 1,000 sq ft | Exempt* | May be exempt from testing (R502.3.1) |
| Passive House / Specialized | 0.6 | Whole-building test, Phius/PHI protocol |
*Confirm with your local building department. Requirements per the 2025 MA Stretch Energy Code Technical Guidance.
How Blower Door Testing Works in Westwood
The fan mounts in an exterior doorway and holds the home at a fixed 50-Pascal pressure difference - about what a 20 mph wind would exert. The airflow required to maintain that pressure, in CFM, converts to ACH50 using the home's conditioned volume.
The code converts the result to Q50 (CFM at 50 Pa) with Q50 = (Volume × ACH50) ÷ 60. A 2,700 sq ft home at 2 ACH50 works out to roughly 810 CFM50.
Keeping Heat In During Westwood Cold Spells
Air-leakage heat loss grows with the gap between indoor and outdoor temperature, which is why a drafty home feels worst in a deep freeze. Warm air you have paid to heat escapes high, cold air rushes in low, and the heating system ends up chasing a load that keeps climbing as the temperature drops.
A tight, tested envelope shrinks the infiltration share of your heating load. That lets the equipment keep up during cold spells, holds rooms at a steadier temperature between cycles, and often lets a designer right-size the heating system rather than oversizing it to cover leakage.
Lower heating load
Less infiltration means a smaller winter heat-loss load and equipment that can keep up.
Retain paid-for heat
Warm air stays in the living space instead of escaping out the top of the house.
Steadier comfort
Fewer cold-floor drafts and a temperature that holds between heating cycles.
Where Westwood Homes Leak Air
During depressurization the leaks are exaggerated, making them easy to find. In Norfolk County's older housing stock the usual suspects are rim joists, top plates, attic hatches, recessed lights, and penetrations for plumbing and wiring. Coastal and exposed sites feel wind-driven infiltration most, so a tight, verified envelope pays back quickly here.
Best Fit for Projects Like
- New single-family homes needing a code compliance test
- Drafty existing homes seeking targeted air sealing
- Mass Save incentive and rebate projects
- Multi-family and townhouse units
- Homes chasing Passive House or net-zero targets
Blower Door Testing Westwood MA Facts
Fail and reseal
If a result comes in above target, the leaks are located and sealed and the home is retested - the goal is a documented pass, not a single reading.
The reference scale
For perspective, a very leaky older home can exceed 11 ACH50, current code sits at 3.0 for new builds, and certified Passive House projects reach 0.2 to 0.6 ACH50.
Older housing stock
Much of New England's housing predates modern air-sealing, so existing homes here often start well above 10 ACH50 - leaving large, cost-effective savings on the table.
Comfort, not just code
Beyond passing code, a tight envelope removes drafts, stabilizes room-to-room temperatures, and reduces the dust and outdoor pollen pulled in through gaps.
Trusted for Blower Door Testing Westwood MA
As a builder, I need accurate and dependable HERS ratings to keep projects on track. This company never disappoints. Always on time, always professional.
I am building a 5-unit conversion in East Boston and used this HERS rating company. Some of the most reasonable, knowledgeable HERS raters I have dealt with in the greater Boston area.
I had an excellent experience. Friendly, knowledgeable, and very responsive. I will definitely be coming back.
Our Massachusetts Service Locations
Serving clients from our Massachusetts locations in Everett, Somerville, and Framingham.
Everett Location
371 Main St
Everett, MA 02149
Somerville Location
519 Broadway
Somerville, MA 02145
Framingham Location
68 South St
Framingham, MA 01702
FAQ About Blower Door Testing Westwood MA
What does the 50 Pascal test pressure represent?
Fifty Pascals is roughly the pressure a 20 mph wind exerts on the whole building. Testing at a fixed pressure makes the result repeatable regardless of the weather that day.
What is the threshold for a remodel?
Remodels and alterations to existing homes are allowed up to 5.0 ACH50, a more realistic target given that older assemblies are harder to seal than new framing.
How tight is a Passive House?
Passive House projects on the Specialized Code path target around 0.6 ACH50 - roughly ten times tighter than base code - verified with a whole-building blower-door test.
Can a blower door test find where my home is drafty?
Yes. Depressurizing the home exaggerates the leaks so a rater can pinpoint exactly where outdoor air is entering, which guides targeted air sealing.
Why does my house feel drafty and cold in winter?
Much of that is the stack effect - warm air leaking out up high draws cold outdoor air in through gaps down low, chilling floors and lower rooms. A blower door test pinpoints exactly where that air is entering so it can be sealed.
How long does a blower door test take?
For a typical single-family home the test itself usually takes well under an hour once the fan is set up and the home is prepared.
Get Started With Blower Door Testing Westwood MA
Book a certified blower door test and get a permit-ready air-tightness report. Call 617-501-6788.