Blower Door Testing Georgetown MA - Quick Facts
Local energy code in Georgetown
- Georgetown enforces the Massachusetts Stretch Energy Code for new construction and major renovations. IECC Climate Zone 5A.
- Massachusetts has three energy-code levels - base (2021 IECC), Stretch, and Specialized (Opt-In) - and Georgetown is on the Stretch Code.
Blower door requirement in Georgetown
- New homes in Georgetown must test at 3.0 ACH50 or tighter under the Massachusetts Stretch Code.
- Air-leakage testing is mandatory, measured with a calibrated blower-door fan to the RESNET / ASTM protocol - there is no inspection-only substitute for the result.
- Companion duct leakage limit: 4.0 CFM25 per 100 sq ft of conditioned floor area total leakage (8.0 when all ducts are inside conditioned space - the test is still required).
- Same-day preliminary results; final report in 24-48 hours, filed with the Georgetown building department.
2026 Mass Save incentives in Georgetown
- A tight result unlocks Mass Save all-electric incentives ($7,500 to $25,000 per new single-family home); an all-electric renovation testing at 3.0 ACH50 or better reaches the Level 2 tier, up to $30,000.
- Incentives require a Mass Save-approved, RESNET-certified HERS rater.
RESNET-certified · 15,000+ ratings completed · 5.0 stars across 136 Google reviews · (617) 501-6788
Blower Door Testing Georgetown MA
Certified blower door testing in Georgetown - we measure your home's air-tightness in ACH50, pinpoint leaks, and document a passing result for your building permit.
Air-tightness at a glance
Blower Door Testing Georgetown MA
A blower door test is the code-required way to prove how airtight a home in Georgetown really is. A calibrated fan depressurizes the house to 50 Pascals so we can measure exactly how much air leaks through the envelope, reported as air changes per hour (ACH50). New construction must reach 3.0 ACH50 or lower, and no home on any compliance path may exceed 5.0 ACH50 (IECC 2021 R402.4.1.2).
| Project type | Max ACH50 | Notes |
|---|---|---|
| New construction | 3.0 or lower | Mandatory blower-door test under R402.4.1.2 |
| Maximum on any compliance path | 5.0 | Code cap under IECC 2021 R402.4.1.2 |
| Addition < 1,000 sq ft | Exempt* | May be exempt from testing (R502.3.1) |
| Passive House (PHI; Phius uses 0.06 CFM50/sq ft) | 0.6 | Whole-building test, Phius/PHI protocol |
*Confirm with your local building department. Requirements per the 2025 MA Stretch Energy Code Technical Guidance.
How Blower Door Testing Works in Georgetown
The fan mounts in an exterior doorway and holds the home at a fixed 50-Pascal pressure difference - about what a 20 mph wind would exert. The airflow required to maintain that pressure, in CFM, converts to ACH50 using the home's conditioned volume.
The code converts the result to Q50 (CFM at 50 Pa) with Q50 = (Volume × ACH50) ÷ 60. A 2,700 sq ft home at 2 ACH50 works out to roughly 810 CFM50.
Keeping Heat In During Georgetown Cold Spells
In winter the biggest enemy of a warm home is often invisible air movement. The stack effect drives heated air out through the top of the envelope and draws frigid air in near the floor, robbing heat all season - Cornell extension research describes it plainly as the effect that steals warmth from your home every winter.
Once the leaks are found and sealed, the home retains heat far longer between heating cycles. Floors stay warmer, temperatures hold steady on windy nights, and the reduced heating load shows up directly on winter utility bills.
Lower heating load
Less infiltration means a smaller winter heat-loss load and equipment that can keep up.
Retain paid-for heat
Warm air stays in the living space instead of escaping out the top of the house.
Steadier comfort
Fewer cold-floor drafts and a temperature that holds between heating cycles.
Where Georgetown Homes Leak Air
During depressurization the leaks are exaggerated, making them easy to find. In Essex County's older housing stock the usual suspects are rim joists, top plates, attic hatches, recessed lights, and penetrations for plumbing and wiring. Coastal and exposed sites feel wind-driven infiltration most, so a tight, verified envelope pays back quickly here.
Best Fit for Projects Like
- Pre-drywall diagnostic testing for builders
- Additions over 1,000 sq ft that trigger testing
- New single-family homes needing a code compliance test
- Mass Save incentive and rebate projects
- Multi-family and townhouse units
Blower Door Testing Georgetown MA Facts
Right-sizing equipment
A verified-tight envelope lets a designer right-size the furnace, boiler, or heat pump instead of oversizing for leakage - lowering both equipment cost and running cost.
Retaining the heat you paid for
A tight, tested envelope keeps the warm air you have already paid to heat inside the living space rather than letting it leak out the top of the house.
Cold snaps magnify leakage
Infiltration heat loss scales with the indoor-outdoor temperature difference, so a leaky envelope bleeds the most heat exactly when you need it most - during a deep freeze.
Quiet, fast, non-destructive
A typical single-family blower door test is non-destructive and usually wraps up in well under an hour once setup is complete.
Trusted for Blower Door Testing Georgetown MA
This company does all my inspections. I use this company a lot and highly recommend them.
One of the most reliable companies that I've worked with in Somerville, Massachusetts.
I am building a 5-unit conversion in East Boston and used this HERS rating company. Some of the most reasonable, knowledgeable HERS raters I have dealt with in the greater Boston area.
Our Massachusetts Service Locations
Serving clients from our Massachusetts locations in Everett, Somerville, and Framingham.
Everett Location
371 Main St
Everett, MA 02149
Somerville Location
519 Broadway
Somerville, MA 02145
Framingham Location
68 South St
Framingham, MA 01702
Real blower door tests by HEEC for Georgetown projects
These are photos from Home Energy Efficiency Consultants blower door testing jobs in Massachusetts — the same equipment and setup our certified raters bring to Georgetown homes.


FAQ About Blower Door Testing Georgetown MA
How does air sealing help during a cold spell?
In winter the stack effect drives warm air out the top of the house and pulls cold air in low down, and it gets stronger the colder it is. A tight, tested envelope blunts that effect, so you retain more of the heat you have paid for and your heating system can keep up during a deep freeze.
Do you work with builders and homeowners?
We work with builders, remodelers, designers, and homeowners - from single tests for permit sign-off to pre-drywall diagnostics that catch problems early.
Can a blower door test find where my home is drafty?
Yes. Depressurizing the home exaggerates the leaks so a rater can pinpoint exactly where outdoor air is entering, which guides targeted air sealing.
Does a tighter house need mechanical ventilation?
Yes. A tight home relies on balanced mechanical ventilation for fresh air, and the code sizes that ventilation (R403.6 / ASHRAE 62.2) using your verified blower-door rate.
What does the 50 Pascal test pressure represent?
Fifty Pascals is roughly the pressure a 20 mph wind exerts on the whole building. Testing at a fixed pressure makes the result repeatable regardless of the weather that day.
Will a tighter home lower my heating load?
Yes. Infiltration is one of the largest parts of a winter heat-loss calculation. Reducing leakage directly shrinks the heating load, which can mean right-sized equipment, lower bills, and a home that holds temperature better in cold weather.
Blower Door Test Requirements for Georgetown Projects
Georgetown is not on the Specialized Code list, so new homes follow the Massachusetts Stretch Code (225 CMR 22.00), adopted by 242 communities, or the base code if Georgetown has not adopted it. The testing requirements below come from 225 CMR 22.00 and the 2021 IECC it amends.



| Requirement | Limit | Source |
|---|---|---|
| New home, prescriptive path | 3.0 ACH50 or lower | IECC 2021 R402.4.1.3 (Climate Zone 5, all of Massachusetts) |
| Maximum on any compliance path | 5.0 ACH50 or 0.28 CFM50 per sq ft of enclosure | IECC 2021 R402.4.1.2 |
| Attached homes and apartments tested unit by unit | 0.30 CFM50 per sq ft of unit enclosure (alternative) | IECC 2021 R402.4.1.2 exception |
| Mass Save ENERGY STAR tier | 1.5 ACH50 or lower | Mass Save new construction program |
| Passive House (PHI) | 0.6 ACH50 or lower | Passive House Institute |
| Passive House (Phius) | 0.06 CFM50 per sq ft of enclosure (0.08 for non-combustible 5+ stories) | Phius 2024 Certification Guidebook |
How the house is set up for the test
- Exterior windows and doors closed, with no sealing beyond normal weatherstripping
- Dampers closed but not taped, and interior doors open
- Exterior ventilation openings sealed, heating and cooling turned off, supply and return registers open
- Tested at 50 Pascals per ANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827, with a signed report for the Georgetown building department
Sources: 225 CMR 22.00 (2025 edition) and the 2021 IECC sections listed. Georgetown is in Essex County, served from our Everett (371 Main St) office.
Blower Door Questions from Georgetown Builders
What blower door number does a new home in Georgetown need?
On the prescriptive path the 2021 IECC requires 3.0 ACH50 or lower in Massachusetts, and no home on any path may exceed 5.0 ACH50. Homes on the HERS path are tested the same way, and the result goes into the HERS model, so a tighter house earns a lower HERS score.
What is ACH50?
Air changes per hour at 50 Pascals: how many times the home's air volume leaks out each hour while a blower door holds the house at 50 Pa. ACH50 = CFM50 × 60 ÷ conditioned volume.
How are townhouses and apartments tested?
Each dwelling unit can be tested on its own and meet 0.30 CFM50 per square foot of the unit's enclosure, which counts walls, floor and ceiling shared with neighbors. Large buildings may also get a whole-building test.
What gets taped or closed during the test?
Windows and exterior doors are closed, dampers are closed but not sealed, and exterior ventilation openings such as bath fan and ERV/HRV terminations are sealed. Interior doors stay open and the heating and cooling system is off.
When should the blower door test happen?
The code test happens at the end of construction. We recommend a pre-drywall test once the air barrier is complete, when leaks are cheap to find and fix, so the final test is a formality.
How much does blower door testing cost in Georgetown?
Pricing depends on the size of the building and the number of units. Send your plans or address and we will quote the test, or bundle it with your HERS rating and duct test in one visit.
Related: Duct leakage testing in Georgetown · HERS rating in Georgetown · Stretch Code help in Georgetown
Get Started With Blower Door Testing Georgetown MA
Book a certified blower door test and get a permit-ready air-tightness report. Call 617-501-6788.
Mass Save®-Listed HERS Rater
Trusted Partner — Verified
Partner
Passive House Verifier
Member★★★★★136 Google
Reviews
The Phius Certified Verifier logo is used under license from Phius.
HERS Ratings in Georgetown, Massachusetts
Home Energy Efficiency Consultants provides Georgetown with certified HERS ratings, blower door and duct leakage testing, and Massachusetts energy-code compliance for new construction, additions, and major renovations — with same-day preliminary reports.
We rate homes across the Commonwealth from our four offices. Reach the one nearest your Georgetown project — Somerville, Framingham, Marlborough, or Everett — or call (617) 501-6788 to schedule a Georgetown rating.
More Massachusetts Towns We Serve
Certified HERS ratings, blower door testing and energy code compliance across all 351 Massachusetts cities and towns.